Customization: | Available |
---|---|
Classification: | Biological Diagnostics |
Type: | Biochemistry Analyzer |
Still deciding? Get samples of US$ 1800/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Standard Parameters | ||||||
NIBP | ETCO2 | AED | PACER | PRINTER | ECG | SPO2 |
Standard equipment
|
|
EKG Cable (5 Leads)
|
1Pcs
|
AED Pad connector
|
1Pcs
|
AED Pad
|
1Pcs
|
Ground Cable
|
1Pcs
|
Power Cable
|
1Pcs
|
Thermal Paper Role
|
1Pcs
|
Cleaning Cloth
|
1Pcs
|
Optional equipment
|
|
ECG Cable
|
Adult/ pediatric/ neonate hard soft/ hard/ shell sensor
|
ECG Alligator Clips
|
Adult/ pediatric/ neonate
|
SpO2 Cable
|
Adult/ pediatric/ neonate
|
NIBP Cuff
|
Adult/ pediatric/ neonate
|
NIBP Tube 150cm
|
Adult/ pediatric/ neonate
|
Paper Role, Thermal printer, Defibrillator Wall mounts, Defibrillator Trolley
|
|
MOQ
|
1Pcs
|
Payment
|
TT, Western union, Credit card
|
Shipping
|
Express, sea, plane
|
SpO2 Module (Options)
1.Measurement range:30~100%±2% between80%~90% other ±5%
2.Alarm range: user defined upper and lower limit.
3.Alarm accuracy: ±10% within the set values.
4.Alarm time accuracy: less than 12 sec.
5.Pulse Oximeter
Recorder
1.Paper: 50mm thermal.
2.Speed:12.5mm/sec.25mm/sec.50mm/sec.
User selectable delay of 6 seconds.
3.Printing method: High resolution thermal print head.
4.Print Modes: Manual or automatic, user configurable.
5.On/off control: front panel and paddle.
6.Automatic function: 9-second recording triggered by alarm activation,
7.defibrillator charge or defibrillator discharge.
EtCO2 Module (Options)
1.CO2 range 0 to 13%(0-98.8mmHg@BTPS)
2.CO2 accuracy <5.0% CO2 (for BTPS) ± 3 mmHg ;
>5.0% CO2 (at BTPS)< 10% of reading
3.Respiratory rate 3~60 BPM Measurement accuracy ±1BPM
NIBP(Options)
1.Method: automatic oscillation
2.Working mode: manual/automatic
3.Measure: adult: 10-250mmHg
4.Ement: pediatric: 10-200mmHg
5.Ement: neonatal: 10-135mmHg
AED Mode
AED function: automatic analysis and charging x3 with programmable automatic energy level selection, on-screen prompts and voice prompts.
Shock capable rhythms: Ventricular fibrillation
with amplitude> =200uV Ventricular tachycardia
with rates > =140bpm and QRS complex
wave duration>=140ms.
Charge control: front panel,
push button on paddle.
Prompts: Voice and visual prompts.
Pacemaker (Options)
1.Type: VVI
2.Pulse type: rectangular, constant current
3.Pulse amplitude: 0 to 180 mA±10% or 5 mA (whichever is greater).
4.Pacing frequency: Variable from 30 ppm to 180 ppm ±1.5% (increments or decrements by a value of 2 ppm)
5.Multifunctional Electrode:(MFE) Pads: multipurpose defibrillation/pacing electrodes
6.Pause: pacing pulse rate is reduced by a factor of 4 upon activation
7.Refractory period: NC (VVI requirements do not have this specification)
8.Pulse width: (20+ 1.5 ms)
9.Output protection: Fully defibrillator protected and isolated
Display
|
|
Screen Type
|
High-resolution display
|
Screen Size
|
7 inches(17.7 cm) diagonally
|
Sweep Speed
|
25mm/sec
|
Information
|
Heart Rate, Lead/Pads, Alarm On/Off, Sp02, AED Functions and Prompts, Alarm Selection and Limits, Delivered Energy
|
Defibrillator
|
|
Waveform
|
Biphasic
|
Energy Display
|
Monitor display indicates both selected and delivered energy
|
Charge Prompt Type
|
Voice and visual prompts
|
Electrode Impedance Measurement Range
|
0-250 ohms
|
ECG Monitoring
|
|
Patient Connection
|
3-1ead ECG cable, or 5-1ead ECG cable, paddles
|
Lead Selection
|
Displayed on monitor, paddles, l, Il, IAVR, AVC, AVF, V
|
ECG Size
|
0.25, 0.5, 1, 1.5, 2, 4 cm/mV diplay on monitor.
|
Heart Rate
|
20-300BPM
|
Heart Rate Alarm
|
On/Off displayed on monitor, user-selectable
|
Smart Alarms
|
Beeper/voice prompts indicate shockable rhythm
|
SpO2 Module
|
|
Measurment Range
|
30-100%, ± 2% between 80%-90%, others ± 5% :
|
Alarm Range
|
User set high limit and low limit
|
Alarm Accuracy
|
± 10% within setting values
|
Alarm time Accuracy
|
less than 12 sec
|
Recorder
|
|
Paper
|
50mm thermal
|
Speed
|
12.5mm/sec, 25mm/sec, 50mm/sec.User-selectable 6-second delay
|
Printing Method
|
High-resolution, thermal array print head
|
Print-out Modes
|
Manual or automatic, user-configurable
|
On/Off Control
|
Front panel and paddle
|
Automatic Function
|
9-second recording initiated by alarm activation or defibrillator charge or defibrillator discharge
|
Battery
|
|
Type
|
Rechargeable, Ni-MH battery, 12V
|
Operating Time
|
For a new, fully charged battery60 defibrillator discharges at maximum energy, or 3 hours minimum of continuous ECG monitoring.Additional parameters will effect operating time with different functions.
|
Shandong Rayman Medical Systems Co.,Ltd.
Rayman medical system,As a world-renowned professional medical equipment manufacturer with more than 20 years production experience in China, Rayman is devoting to integrate R&D, production, sales and service of all kinds of medical equipments.
Rayman in 3 categories cover more than 30 series total 300+ basic models and items include patient monitors, ECG, ultrasound machine, Endoscope, laryngoscope, X-Ray, syringe pumps, infusion pumps, AED, fetal monitor, hospital beds,hospital trolley carts,wheelchairs, ect. ,which are exported to more than 150 countries all over the world.
Rayman has two R&D centers with a R&D team of more than 60 personnel. At present we have nearly 200 patents and authorized trademarks. Rayman also has three production bases cover an area of 50000 square meters equipped with independent laboratories, testing centers, professional intelligent SMT production lines, dust-free workshops, precision mold processing and injection molding factories, forming a complete and cost-controllable production and quality control system. The output is nearly 20 million units to meet the customized needs of global customers.
1.Who are we?
We are a company specializing in patient monitors, ECG, ultrasound machine, Endoscope, laryngoscope, X-Ray, syringe pumps, infusion pumps, AED, fetal monitor, hospital beds,hospital trolley carts,wheelchairs, ect.
2. How can we guarantee quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment.
3. Why should you buy from us not from other suppliers?
We Rayman is in the medical products field for more than 20 years.
4. What services can we provide?
Delivery Terms: FOB,CFR,CIF,EXW,DDP Payment Currency:USD,EUR
Payment Terms: T/T,L/C,D/P D/A,MoneyGram,Credit Card,PayPal,Western Union,Cash,Escrow.