Analyzer Medical External Aed Defibrillator Machine for Emergency

Product Details
Customization: Available
Classification: Biological Diagnostics
Type: Biochemistry Analyzer
Still deciding? Get samples of US$ 1800/Piece
Request Sample
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 15 foreign trading staff(s) and 7 staff(s) with over 6 years of overseas trading experience
Self-branded
The supplier has 1 Self-brands, check the Audit Report for more information
to see all verified strength labels (12)
  • Analyzer Medical External Aed Defibrillator Machine for Emergency
  • Analyzer Medical External Aed Defibrillator Machine for Emergency
  • Analyzer Medical External Aed Defibrillator Machine for Emergency
  • Analyzer Medical External Aed Defibrillator Machine for Emergency
  • Analyzer Medical External Aed Defibrillator Machine for Emergency
  • Analyzer Medical External Aed Defibrillator Machine for Emergency
Find Similar Products
  • Overview
  • Product Description
  • Product Specification
  • Packaging & Shipping
  • Certifications
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
RM13-001
Certification
CE, ISO13485
Group
Suitable for People of All Ages
Province
Shandong
Brand
Rayman
Model
RM13-001
Screen
8 Inches
Feature
Emgency
Product
Aed Defibrillator
Power Source
Electricity
Waveform
Biphasic
Sweep Speed
25mm/Sec
Packing Size
490*540*490mm
Weight
10.5kg
Battery
Rechargeable Lithium Battery
Using
Examination Therapy Equipments
Application
Hospital& Clinic&Operating Room
Supply Ability
1000 Piece/Pieces Per Month
Transport Package
Package,
Specification
49*54*49CM
Trademark
Ryaman
Origin
China
HS Code
9018193010
Production Capacity
200000pieces/Year

Product Description

Analyzer Medical External AED Defibrillator machine for emergency 
Product Description
Description:
A defibrillator is a medical device used to terminate fatal arrhythmias such as ventricular fibrillation and ventricular flutter. It releases a certain amount of energy of electric shock to the heart, causing the electrical activity of myocardial cells to depolarize instantly and simultaneously, eliminating arrhythmias and restoring normal sinus rhythm.
Analyzer Medical External Aed Defibrillator Machine for Emergency
Analyzer Medical External Aed Defibrillator Machine for Emergency
Standard Parameters
NIBP ETCO2 AED PACER PRINTER ECG SPO2

Operation steps of the defibrillator:
1. Turn on the power: Press the power button to ensure that the device is in normal working condition.
2. Select energy: For manual defibrillators, medical staff will select the appropriate shock energy based on factors such as the patient's weight and type of arrhythmia.
3. Apply conductive paste: Apply conductive paste evenly on the electrode plate to reduce skin resistance and ensure that the current can be effectively conducted.
4. Place the electrode plate: Place one electrode plate on the patient's apex (5th-6th intercostal space on the left anterior axillary line) and the other on the 2nd intercostal space on the right edge of the sternum.
5. Charge: Press the charge button to charge the defibrillator to the set energy.
6. Confirm the safety of people around: shout "Everyone leave" loudly to ensure that no one comes into contact with the patient.
7. Discharge: Press the discharge button to deliver an electric shock.
Analyzer Medical External Aed Defibrillator Machine for Emergency
Analyzer Medical External Aed Defibrillator Machine for Emergency
Analyzer Medical External Aed Defibrillator Machine for Emergency
  
Product Specification
Analyzer Medical External Aed Defibrillator Machine for Emergency
Display:
Screen Type: High-resolution display
Screen Size: 8 inch
Languages: 5toChoose
Sweep Speed: 25mm/sec
Information: Heart Rate.Lead/Pads.Alarm On/OffSp2 AED Functions and Prompts Alarm Selection and Limits Delivered Energy

SpO2 Module (Options)
1.Measurement range:30~100%±2% between80%~90% other ±5%
2.Alarm range: user defined upper and lower limit.
3.Alarm accuracy: ±10% within the set values.
4.Alarm time accuracy: less than 12 sec.
5.Pulse Oximeter


Recorder
1.Paper: 50mm thermal.
2.Speed:12.5mm/sec.25mm/sec.50mm/sec.
User selectable delay of 6 seconds.
3.Printing method: High resolution thermal print head.
4.Print Modes: Manual or automatic, user configurable.
5.On/off control: front panel and paddle.
6.Automatic function: 9-second recording triggered by alarm activation,
7.defibrillator charge or defibrillator discharge.

 

Manual Mode
1.Energy selection: Selectable at 2 5 7 10 20 30 50 70 100 150 200 300 360 joules.
2.Synchronized mode: Synchronizes the defibrillator pulse with the R-wave.
3.The message "SYNC" is displayed on the monitor.


NIBP(Options)
1.Method: automatic oscillation
2.Working mode: manual/automatic
3.Measure: adult: 10-250mmHg
4.Ement: pediatric: 10-200mmHg
5.Ement: neonatal: 10-135mmHg


EtCO2 Module (Options)
1.CO2 range 0 to 13%(0-98.8mmHg@BTPS)

2.CO2 accuracy <5.0% CO2 (for BTPS) ± 3 mmHg ;
>5.0% CO2 (at BTPS)< 10% of reading
3.Respiratory rate 3~60 BPM Measurement accuracy ±1BPM

 
Analyzer Medical External Aed Defibrillator Machine for Emergency


AED Mode
AED function: automatic analysis and charging x3 with programmable automatic energy level selection, on-screen prompts and voice prompts.
Shock capable rhythms: Ventricular fibrillation
with amplitude> =200uV Ventricular tachycardia
with rates > =140bpm and QRS complex
wave duration>=140ms.
Charge control: front panel,
push button on paddle.
Prompts: Voice and visual prompts.

Pacemaker (Options)
1.Type: VVI
2.Pulse type: rectangular, constant current
3.Pulse amplitude: 0 to 180 mA±10% or 5 mA (whichever is greater).
4.Pacing frequency: Variable from 30 ppm to 180 ppm ±1.5% (increments or decrements by a value of 2 ppm)
5.Multifunctional Electrode:(MFE) Pads: multipurpose defibrillation/pacing electrodes
6.Pause: pacing pulse rate is reduced by a factor of 4 upon activation
7.Refractory period: NC (VVI requirements do not have this specification)
8.Pulse width: (20+ 1.5 ms)
9.Output protection: Fully defibrillator protected and isolated

Analyzer Medical External Aed Defibrillator Machine for Emergency
Analyzer Medical External Aed Defibrillator Machine for Emergency
 

Defibrillator
 
1.Waveform: Biphasic(BTE)
2.Recharge Time: Less than 7 seconds with a new, fully charged 3.battery.
4.Energy display: Monitor display shows both selected and delivered energy.
5.Type of charging prompts: Voice and visual prompts.
6.Electrode impedance measurement range: 0-250 ohms.

ECG Monitoring
 
1.Patient connection:3-lead ECG cable or 5-lead ECG cable paddles.
2.Lead selection: Display on monitor paddles I II III AVR AVL AVF V.
3.ECG size: 0.25 0.5 1 1.5 2 4 cm/mV displayed on the monitor.
4.Heart rate: 20-300 BPM.
5.Heart rate alarm: display on monitor on/off, user selectable.
6.Smart alarms: beep/voice announcements indicate shockable rhythms.

 
Battery 1.Type: rechargeable Ni MH battery 12V.
2.Operating time: for a new, fully charged battery:
3.60 defibrillator discharges at maximum energy or
4.at least 3 hours of continuous ECG monitoring.
5.Other parameters affect operating time for various functions.

 
Packaging & Shipping
Analyzer Medical External Aed Defibrillator Machine for Emergency
 
Analyzer Medical External Aed Defibrillator Machine for Emergency
Certifications

Analyzer Medical External Aed Defibrillator Machine for Emergency

Company Profile

Analyzer Medical External Aed Defibrillator Machine for Emergency

Shandong Rayman Medical Systems Co.,Ltd.

Rayman medical system,As a world-renowned professional medical equipment manufacturer with more than 20 years production experience in China, Rayman is devoting to integrate R&D, production, sales and service of all kinds of medical equipments.

Rayman in 3 categories cover more than 30 series total 300+ basic models and items include patient monitors, ECG, ultrasound machine, Endoscope, laryngoscope, X-Ray, syringe pumps, infusion pumps, AED, fetal monitor, hospital beds,hospital trolley carts,wheelchairs, ect. ,which are exported to more than 150 countries all over the world.

Rayman
 has two R&D centers with a R&D team of more than 60 personnel. At present we have nearly 200 patents and authorized trademarks. Rayman also has three production bases cover an area of 50000 square meters equipped with independent laboratories, testing centers, professional intelligent SMT production lines, dust-free workshops, precision mold processing and injection molding factories, forming a complete and cost-controllable production and quality control system. The output is nearly 20 million units to meet the customized needs of global customers.

FAQ

1.Who are we?
We are a company specializing in patient monitors, ECG, ultrasound machine, Endoscope, laryngoscope, X-Ray, syringe pumps, infusion pumps, AED, fetal monitor, hospital beds,hospital trolley carts,wheelchairs, ect.

2. How can we guarantee quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment.


3. Why should you buy from us not from other suppliers?
We Rayman is in the medical products field for more than 20 years.

4. What services can we provide?
Delivery Terms: FOB,CFR,CIF,EXW,DDP Payment Currency:USD,EUR
Payment Terms: T/T,L/C,D/P D/A,MoneyGram,Credit Card,PayPal,Western Union,Cash,Escrow.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier