Customization: | Available |
---|---|
Classification: | Biological Diagnostics |
Type: | Biochemistry Analyzer |
Still deciding? Get samples of US$ 1800/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Standard Parameters | ||||||
NIBP | ETCO2 | AED | PACER | PRINTER | ECG | SPO2 |
item | value |
Type | First-Aid Devices |
Place of Origin | China |
Instrument classification | Class II |
Warranty | 1 Year |
After-sale Service | Online technical support |
Product name | Defibrillator |
Application | Emergency Rescue |
Usage | First-aid Appliance |
Feature | Emgency |
Description:
A defibrillator is a medical device used to terminate fatal arrhythmias such as ventricular fibrillation and ventricular flutter. It releases a certain amount of energy of electric shock to the heart, causing the electrical activity of myocardial cells to depolarize instantly and simultaneously, eliminating arrhythmias and restoring normal sinus rhythm.
AED Mode
AED function: automatic analysis and charging x3 with programmable automatic energy level selection, on-screen prompts and voice prompts.
Shock capable rhythms: Ventricular fibrillation
with amplitude> =200uV Ventricular tachycardia
with rates > =140bpm and QRS complex
wave duration>=140ms.
Charge control: front panel,
push button on paddle.
Prompts: Voice and visual prompts.
Pacemaker (Options)
1.Type: VVI
2.Pulse type: rectangular, constant current
3.Pulse amplitude: 0 to 180 mA±10% or 5 mA (whichever is greater).
4.Pacing frequency: Variable from 30 ppm to 180 ppm ±1.5% (increments or decrements by a value of 2 ppm)
5.Multifunctional Electrode:(MFE) Pads: multipurpose defibrillation/pacing electrodes
6.Pause: pacing pulse rate is reduced by a factor of 4 upon activation
7.Refractory period: NC (VVI requirements do not have this specification)
8.Pulse width: (20+ 1.5 ms)
9.Output protection: Fully defibrillator protected and isolated
Precautions:
1. Before operation:
Make sure the patient removes metal objects on the body, such as necklaces, bracelets, watches, etc., to avoid local skin burns;
Check whether the defibrillator has sufficient power and whether the lead wires and electrode pads are well connected;
Confirm that the patient is in a supine position and the body does not touch the surrounding metal objects.
2. During operation:
The electrode pad should be in close contact with the skin without leaving any gaps, and the conductive paste should be evenly applied to ensure good current conduction;
During discharge, the operator and other personnel must not touch the patient and the bed to avoid electric shock;
During the defibrillation process, the patient's vital signs and ECG monitoring should be closely observed.
3. After operation:
Observe the patient's heart rhythm recovery and evaluate the defibrillation effect;
Clean the electrode pads and organize the defibrillator to keep it in standby mode.
Shandong Rayman Medical Systems Co.,Ltd.
Rayman medical system,As a world-renowned professional medical equipment manufacturer with more than 20 years production experience in China, Rayman is devoting to integrate R&D, production, sales and service of all kinds of medical equipments.
Rayman in 3 categories cover more than 30 series total 300+ basic models and items include patient monitors, ECG, ultrasound machine, Endoscope, laryngoscope, X-Ray, syringe pumps, infusion pumps, AED, fetal monitor, hospital beds,hospital trolley carts,wheelchairs, ect. ,which are exported to more than 150 countries all over the world.
Rayman has two R&D centers with a R&D team of more than 60 personnel. At present we have nearly 200 patents and authorized trademarks. Rayman also has three production bases cover an area of 50000 square meters equipped with independent laboratories, testing centers, professional intelligent SMT production lines, dust-free workshops, precision mold processing and injection molding factories, forming a complete and cost-controllable production and quality control system. The output is nearly 20 million units to meet the customized needs of global customers.
1.Who are we?
We are a company specializing in patient monitors, ECG, ultrasound machine, Endoscope, laryngoscope, X-Ray, syringe pumps, infusion pumps, AED, fetal monitor, hospital beds,hospital trolley carts,wheelchairs, ect.
2. How can we guarantee quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment.
3. Why should you buy from us not from other suppliers?
We Rayman is in the medical products field for more than 20 years.
4. What services can we provide?
Delivery Terms: FOB,CFR,CIF,EXW,DDP Payment Currency:USD,EUR
Payment Terms: T/T,L/C,D/P D/A,MoneyGram,Credit Card,PayPal,Western Union,Cash,Escrow.