• Rayman Automated External Defibrillator First Aid Aed Device for Ambulance
  • Rayman Automated External Defibrillator First Aid Aed Device for Ambulance
  • Rayman Automated External Defibrillator First Aid Aed Device for Ambulance
  • Rayman Automated External Defibrillator First Aid Aed Device for Ambulance
  • Rayman Automated External Defibrillator First Aid Aed Device for Ambulance
  • Rayman Automated External Defibrillator First Aid Aed Device for Ambulance

Rayman Automated External Defibrillator First Aid Aed Device for Ambulance

Classification: Physiological Functions of Diagnosis and Monitoring Equipment
Type: Aed
Certification: CE, MSDS, ISO13485, CE ISO MSDS
Group: Suitable for People of All Ages
Brand: Rayman
MOQ: 10PCS
Samples:
US$ 549/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2024

Suppliers with verified business licenses

Shandong, China
to see all verified strength labels (11)
  • Overview
  • Product Description
  • Detailed Photos
  • Product Parameters
  • Packaging & Shipping
  • Certifications
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
RM13-002
Color
Black
Size
280 X 209 X 80 mm
Weight
2.5kg
Packing
Carton
Output
Biphasic Truncated Exponential
Energy Sequence(Child)
50j,50j,50j
Energy Sequence(Adult)
150j,200j,200j
Analysis Time
6 Sec
The Maximum Voltage
1400V
Operating Temperature
0~40degree Celsius
Storage Temperature(Without Battery)
-20~55 Degree Celsius
Storage Humidity(Without Battery)
up to 93%
Transport Package
Carton
Specification
Size: 280 x 209 x 80 mm Weight: 2.5kg
Trademark
Rayman
Origin
China
HS Code
90189099
Production Capacity
10000pieces/Month

Product Description

Rayman Automated External Defibrillator First Aid AED Device For Ambulance
Rayman Automated External Defibrillator First Aid Aed Device for Ambulance

Product Description

Quick Details:
1. Standard Four buttons :On/Off, Shock,Adult/child,CPR
2. Visual Prompts:LED prompts;Automatic Self-test
3. Built non-rechargeable Battery:2.8 Ah
4. The Maximum Voltage:1400±50V
4. Output disabled when the patient impedance is outside limits 20Ω to 200Ω
5. 120 discharges at 200 Joules

6.Shelf Life (25°C+15C): 3 years standby (after installation)

 

Rayman Automated External Defibrillator First Aid Aed Device for Ambulance
The maximum time from the initiation of rhythm analy-sis to readiness for discharge with a new battery.Less than 10 seconds 
The maximum time from the initiation of rhythm analy-sis to readiness for discharge after 6 shocks Less than 10 seconds 
The maximum time from initially switching power on to readiness for discharge. Less than18 seconds

Product characteristics

1.Speciality 2.Lightweight 3.Convenient 4.Easy to use

Lightweight and convenient,Rapid defibrillation,Voice prompts,Two modes,Fast starting,Low energy defibrillation,Energy accuracy 98%,Qualification Certificate

Rayman Automated External Defibrillator First Aid Aed Device for Ambulance

 

Detailed Photos

Rayman Automated External Defibrillator First Aid Aed Device for Ambulance
Rayman Automated External Defibrillator First Aid Aed Device for Ambulance

Why choose our product ?
Features:
-Big screen LCD display
-extensive voice and visual prompts for the operator
-three step defibrillation process -two button operation
-Biphasic energy output
-lock-out protection to prevent inadvertent defibrillation
-automatic self
-test: daily battery condition test&monthly AED whole intersystem test

Rayman Automated External Defibrillator First Aid Aed Device for Ambulance
Rayman Automated External Defibrillator First Aid Aed Device for Ambulance

Application Scenarios
Rescue Team Rescue
Emergency Room Visits
Firefighting Emergency
Professional Medical Assistance
Rayman Automated External Defibrillator First Aid Aed Device for Ambulance
Advantages
Adult/Child mode button
Infrared for data transmission
Defererent languages to choose
Daily,weekly and monthly self-test
Rayman Automated External Defibrillator First Aid Aed Device for Ambulance
Product performance description
The maximum time from the initiation of rhythm analy-sis to readiness for discharge with a new battery. Less than 10seconds  The maximum time from the initiation of rhythm analy-sis to readiness for discharge after 6 shocks Less than 10 seconds  The maximum time from initially switching power on to readiness for discharge. Less than18 seconds
Rayman Automated External Defibrillator First Aid Aed Device for AmbulanceHealth protection/Rapid Response/Fully Configured
Conveniently Portable/Wisdom Network/High-definition Display

Rayman Automated External Defibrillator First Aid Aed Device for AmbulanceTaking Care of Health
Automatic External Defibrillator
Professional medical care,rescue,always have a first aid kit

Product Parameters

Rayman Automated External Defibrillator First Aid Aed Device for AmbulanceDefibrillator

Category Specification
Output Biphasic Truncated exponential
Energy Sequence(child) 50J,50J,50J
Energy Sequence(Adult) 150J,200J,200J
Charge Time 6 sec. to 150J
8 sec. to 200 J(New battery)
Analysis Time 6 sec.
The maximum time from the initiation of rhythm analy-sis to readiness for discharge with a new battery. Less than 10seconds
The maximum time from the initiation of rhythm analy-sis  to readiness for discharge after 6 shocks. Less than 10 seconds
The maximum time from initially switching power on toreadiness for discharge. Less than18 seconds
Visual Prompts LED prompts;Automatic Self-test
Controls Four buttons :On/Off, Shock,Adult/child,CPR
Output Energy Accuracy ±10% into any impedance from 25 to 175Q
The Maximum Voltage 1400±50V
Output disabled when the patient impedance is outsidelimits 20Ω to 200Ω
Rayman Automated External Defibrillator First Aid Aed Device for Ambulance
Rayman Automated External Defibrillator First Aid Aed Device for Ambulance

Battery
Non-rechargeable 2.8 Ah
Capacity 120 discharges at 200 Joules
Shelf Life (25°C+15C) 5 years standby (after installation)
Physical
Dimensions 280 x 209 x 80 mm
Weight 2.5 kg
Operating Temperature 0°C to 40°C
Operating Humidity Relative humidity between 30% and 95%(non-condensing)
Storage Temperature(without battery) -20°C to 55°C
Storage Humidity(without battery) Up to 93%(non-condensing)
Rayman Automated External Defibrillator First Aid Aed Device for Ambulance

Packaging & Shipping

Rayman Automated External Defibrillator First Aid Aed Device for Ambulance
AED has a special packaging bag, which can protect the product from external impact.

Certifications

Rayman Automated External Defibrillator First Aid Aed Device for Ambulance

Company Profile

 Rayman Medical Systems
Rayman Automated External Defibrillator First Aid Aed Device for Ambulance

As a world-renowned professional medical equipment manufacturer with more than 30 years production experience in China, Rayman is devoting to integrate R&D, production, sales and service of all kinds of medical equipments .
Rayman products in 3 categories cover more than 30 series total 300+ basic models and items include oximeters, patient monitors, ECG, syringe pumps, blood pressure monitors, oxygen concentrator, nebulizers, Hospital Bed, Hospital Trolley, Wheelchair, etc., which are exported to more than 150 countries all over the world.
Rayman has two R&D centers with a R&D team of more than 60 personnel. At present we have nearly 200 patents and authorized trademarks. Rayman also has three production bases cover an area of 50000 square meters equipped with independent laboratories, testing centers, professional intelligent SMT production lines, dust-free workshops, precision mold processing and injection molding factories, forming a complete and cost-controllable production and quality control system. The output is nearly 20 million units to meet the customized needs of global customers.
Rayman has an independent after-sales service system for distribution, OEM and end customers under the guidance of the values of "sincerity, love, efficiency, and responsibility" . The online and offline service teams are responsible for the entire product life cycle.
 Rayman has a whole-process quality monitoring system which is more conducive to Rayman brand global layout. Up to now, more than 120 products have CE, FDA, CFDA, ANVISN, TUV ISO13485, CMD ISO9001 and other certifications. Product inspection covers IQC, IPQC, OQC, FQC, MES, QCC and other standard control processes.
 Rayman was rated as National High-tech Enterprise,National Intellectual Property Advantage Enterprise, Shandong Medical Device Manufacturing Enterprise Member Unit. And Rayman has maintained long-term cooperative relations with Renhe Hospital, and other well-known brands.

Welcome to contact us!
Rayman Automated External Defibrillator First Aid Aed Device for Ambulance

FAQ

Q: What is our factory product range? 
A: Patient monitor,ECG,X-ray machine,Infusion pump,Operating table, Hospital bed, Hospital manual bed, Ambulance stretcher, Medical trolley cart, Shadowless lamp,and Hospital accessories etc.
Q: What information should I provide if I want to order the products? 
A:1) Product information: Quantity, Specification (size, material, color and packing requirements)   

2) Delivery time required.     
3) Shipping information: Company name, Address, Phone number, Destination seaport/air port.    
4) Forwarder's contact details if there is any in China.
Q: Is your product customized? 
A:Yes, we can customize the products according to your detailed requirements, so we will appreciate it very much if you tell us more information about quantity and packing requirements etc.
Q: How about your payment terms?  
A: 30% deposit, with the balance before delivery, we accept T/T, Western Union and L/C at sight
Q: Can I use our own logo? 
A: Yes, we can produce by using your own logo if you need.
Q: What's the sample policy? 
A: We can send you 1pc of sample for your test, but you need to pay for the sample fee and delivery charge, as it's our company's rule. Pls contact us for the sample details.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now