Standard Parameters | ||||||
NIBP | ETCO2 | AED | PACER | PRINTER | ECG | SPO2 |
Operating Step:
1. Turn on: Place the AED next to the patient and operate on the patient's side. To turn on the AED, press the power switch or open the cover of the display. The instrument will give a voice prompt to guide the next steps.
2. Paste: Place the electrode pads.
1) Adult electrode pad placement: According to the diagram on the AED electrode pad, stick one electrode pad on the upper right side of the patient's exposed chest and the other electrode pad on the outside of the patient's left nipple.
2) Infant and child electrode pad placement: Stick the two electrode pads on the center of the chest and the left shoulder blade behind the infant and child respectively. Larger children can also place the electrode pads in the same position as adults.
3. Plug: Insert the electrode pad plug into the AED host jack, and the AED will automatically analyze the heart rate. At this time, emergency personnel and bystanders should ensure that they do not come into contact with the patient to avoid affecting the instrument's analysis of the heart rate. Heart rhythm analysis takes 5 to 15 seconds.
4. Charge: When the AED analyzes a heart rhythm that requires defibrillation, the capacitor will often charge automatically, and there will be a sound or indicator light prompt. Before pressing the "shock" button, make sure that no one is touching the patient. After the first shock, immediately continue cardiopulmonary resuscitation (CPR).
Display
|
|
Screen Type
|
High-resolution display
|
Screen Size
|
7 inches(17.7 cm) diagonally
|
Sweep Speed
|
25mm/sec
|
Information
|
Heart Rate, Lead/Pads, Alarm On/Off, Sp02, AED Functions and Prompts, Alarm Selection and Limits, Delivered Energy
|
Defibrillator
|
|
Waveform
|
Biphasic
|
Energy Display
|
Monitor display indicates both selected and delivered energy
|
Charge Prompt Type
|
Voice and visual prompts
|
Electrode Impedance Measurement Range
|
0-250 ohms
|
ECG Monitoring
|
|
Patient Connection
|
3-1ead ECG cable, or 5-1ead ECG cable, paddles
|
Lead Selection
|
Displayed on monitor, paddles, l, Il, IAVR, AVC, AVF, V
|
ECG Size
|
0.25, 0.5, 1, 1.5, 2, 4 cm/mV diplay on monitor.
|
Heart Rate
|
20-300BPM
|
Heart Rate Alarm
|
On/Off displayed on monitor, user-selectable
|
Smart Alarms
|
Beeper/voice prompts indicate shockable rhythm
|
SpO2 Module
|
|
Measurment Range
|
30-100%, ± 2% between 80%-90%, others ± 5% :
|
Alarm Range
|
User set high limit and low limit
|
Alarm Accuracy
|
± 10% within setting values
|
Alarm time Accuracy
|
less than 12 sec
|
Recorder
|
|
Paper
|
50mm thermal
|
Speed
|
12.5mm/sec, 25mm/sec, 50mm/sec.User-selectable 6-second delay
|
Printing Method
|
High-resolution, thermal array print head
|
Print-out Modes
|
Manual or automatic, user-configurable
|
On/Off Control
|
Front panel and paddle
|
Automatic Function
|
9-second recording initiated by alarm activation or defibrillator charge or defibrillator discharge
|
Battery
|
|
Type
|
Rechargeable, Ni-MH battery, 12V
|
Operating Time
|
For a new, fully charged battery60 defibrillator discharges at maximum energy, or 3 hours minimum of continuous ECG monitoring.Additional parameters will effect operating time with different functions.
|
Shandong Rayman Medical Systems Co.,Ltd.
Rayman medical system,As a world-renowned professional medical equipment manufacturer with more than 20 years production experience in China, Rayman is devoting to integrate R&D, production, sales and service of all kinds of medical equipments.
Rayman in 3 categories cover more than 30 series total 300+ basic models and items include patient monitors, ECG, ultrasound machine, Endoscope, laryngoscope, X-Ray, syringe pumps, infusion pumps, AED, fetal monitor, hospital beds,hospital trolley carts,wheelchairs, ect. ,which are exported to more than 150 countries all over the world.
Rayman has two R&D centers with a R&D team of more than 60 personnel. At present we have nearly 200 patents and authorized trademarks. Rayman also has three production bases cover an area of 50000 square meters equipped with independent laboratories, testing centers, professional intelligent SMT production lines, dust-free workshops, precision mold processing and injection molding factories, forming a complete and cost-controllable production and quality control system. The output is nearly 20 million units to meet the customized needs of global customers.
1.Who are we?
We are a company specializing in patient monitors, ECG, ultrasound machine, Endoscope, laryngoscope, X-Ray, syringe pumps, infusion pumps, AED, fetal monitor, hospital beds,hospital trolley carts,wheelchairs, ect.
2. How can we guarantee quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment.
3. Why should you buy from us not from other suppliers?
We Rayman is in the medical products field for more than 20 years.
4. What services can we provide?
Delivery Terms: FOB,CFR,CIF,EXW,DDP Payment Currency:USD,EUR
Payment Terms: T/T,L/C,D/P D/A,MoneyGram,Credit Card,PayPal,Western Union,Cash,Escrow.